Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters

Language
Document Type
Year range
1.
Diagnostics (Basel, Switzerland) ; 13(5), 2023.
Article in English | EuropePMC | ID: covidwho-2259361

ABSTRACT

Background: Monitoring antibody response following SARS-CoV-2 vaccination is strategic, and neutralizing antibodies represent the gold standard. The neutralizing response to Beta and Omicron VOCs was evaluated versus the gold standard by a new commercial automated assay. Methods: Serum samples from 100 healthcare workers from the Fondazione Policlinico Universitario Campus Biomedico and the Pescara Hospital were collected. IgG levels were determined by chemiluminescent immunoassay (Abbott Laboratories, Wiesbaden, Germany) and serum neutralization assay as the gold standard. Moreover, a new commercial immunoassay, the PETIA test Nab (SGM, Rome, Italy), was used for neutralization evaluation. Statistical analysis was performed with R software, version 3.6.0. Results: Anti-SARS-CoV-2 IgG titers decayed during the first ninety days after the vaccine second dose. The following booster dose significantly (p < 0.001) increased IgG levels. A correlation between IgG expression and neutralizing activity modulation was found with a significant increase after the second and the third booster dose (p < 0.05. Compared to the Beta variant of the virus, the Omicron VOC was associated with a significantly larger quantity of IgG antibodies needed to achieve the same degree of neutralization. The best Nab test cutoff for high neutralization titer (≥1:80) was set for both Beta and Omicron variants. Conclusion: This study correlates vaccine-induced IgG expression and neutralizing activity using a new PETIA assay, suggesting its usefulness for SARS-CoV2 infection management.

2.
Diagnostics (Basel) ; 13(5)2023 Feb 26.
Article in English | MEDLINE | ID: covidwho-2259362

ABSTRACT

BACKGROUND: Monitoring antibody response following SARS-CoV-2 vaccination is strategic, and neutralizing antibodies represent the gold standard. The neutralizing response to Beta and Omicron VOCs was evaluated versus the gold standard by a new commercial automated assay. METHODS: Serum samples from 100 healthcare workers from the Fondazione Policlinico Universitario Campus Biomedico and the Pescara Hospital were collected. IgG levels were determined by chemiluminescent immunoassay (Abbott Laboratories, Wiesbaden, Germany) and serum neutralization assay as the gold standard. Moreover, a new commercial immunoassay, the PETIA test Nab (SGM, Rome, Italy), was used for neutralization evaluation. Statistical analysis was performed with R software, version 3.6.0. RESULTS: Anti-SARS-CoV-2 IgG titers decayed during the first ninety days after the vaccine second dose. The following booster dose significantly (p < 0.001) increased IgG levels. A correlation between IgG expression and neutralizing activity modulation was found with a significant increase after the second and the third booster dose (p < 0.05. Compared to the Beta variant of the virus, the Omicron VOC was associated with a significantly larger quantity of IgG antibodies needed to achieve the same degree of neutralization. The best Nab test cutoff for high neutralization titer (≥1:80) was set for both Beta and Omicron variants. CONCLUSION: This study correlates vaccine-induced IgG expression and neutralizing activity using a new PETIA assay, suggesting its usefulness for SARS-CoV2 infection management.

3.
Int Nurs Rev ; 2023 Jan 25.
Article in English | MEDLINE | ID: covidwho-2213665

ABSTRACT

AIMS: To measure nurses' compliance with standard precautions during the COVID-19 pandemic, compare findings with previous assessments and describe the barriers affecting nurses' compliance. BACKGROUND: Healthcare providers' compliance with standard precautions is still limited worldwide. Implementation of infection control policies in hospitals is needed internationally, especially during a pandemic. Surprisingly, studies exploring nurses' compliance with standard precautions are lacking during COVID-19. METHODS: A multicenter cross-sectional study was adopted in two Italian hospitals. Nurses' compliance with standard precautions was measured through The Compliance with Standard Precautions Scale (Italian version). An open-ended question explored the barriers to nurses' compliance with standard precautions. Reporting, followed the STROBE guidelines. RESULTS: A total of 201 nurses were enrolled in 2020. Nurses' compliance with standard precautions was suboptimal. A statistically significant improvement in the compliance rate with standard precautions was observed between pre- and during COVID-19 assessments. High compliance was found in the appropriate use of surgical masks, gloves and sharps disposal. Nurses perceived personal, structural and organizational barriers to standard precautions adherence. CONCLUSION: Nurses' compliance with standard precautions was not 100%, and different factors impeded nurses to work safely. Our findings provide institutional leaders and educators with the basis for implementing policies to optimize nurse safety, well-being and patient care. IMPLICATIONS FOR NURSING AND HEALTH POLICIES: Nurses have the right to work safely, and when the shortage of personal protective equipment and nurses during an emergency threatens healthcare quality worldwide, policymakers are challenged to act by establishing an effective allocation of resources for consistent compliance with standard precautions. Moreover, nurses should actively engage in the implementation of infection control policies to improve safe behaviours among citizens and students accessing hospitals.

SELECTION OF CITATIONS
SEARCH DETAIL